FUNCTION
Trigger auto-cutter drive (Auto-cutting models only)
CODE
<ESC> “d” “0” or <ESC> “d” <0>
(1B)
H (64)H (30)H or (1B)H (64)H (00)H
<ESC> “d” “1” or <ESC> “d” <1>
(1B)
H (64)H (31)H or (1B)H (64)H (01)H
OUTLINE
This code causes the printer to trigger auto-cutter.
FUNCTION
Select validation printing (Models with validation function
only)
CODE
<GS> data <LF>
(1D)
H data (0A)
OUTLINE
Prints up to 32 columns of the 7 × 9 (half dot) font size
characters on one line.
NOTE
(1) Character data and immediate execution command
<CAN> <SUB> <LF> are valid for data.
(2) Printing modes (such as emphasized, inverted, expanded
character modes, etc.) which were set before validation
printing are invalid during validation printing. (These
modes become valid again after validation printing is
completed.)
(Refer to “5. VALIDATION PRINTING”)